How it works
From measurement microphone to report, in five steps.
Measure
A monitoring station is a measurement microphone connected to a small computer. It measures LAeq and LCeq every second, plus the third-octave bands. The accuracy is comparable to class 2 according to IEC 61672-1. The meter is calibrated on site.
Send
The monitoring station sends the measurements to the platform via Wi-Fi, a cable or 4G. If the connection drops, it stores the measurements and sends them later.
Assess
You set a limit per measuring point, for example LAeq per 15 minutes and optionally LCeq. The platform assesses every window. Green is within, orange is close, red is over.
View and notify
You see the status in the admin, on a screen in the venue or via a share link. If the limit is exceeded, you get a push notification or an e-mail.
Storing and reporting
Everything is stored: per second, per minute and per quarter of an hour. You create a monthly overview, an event report or a CSV file.
What the system does
Measure
A monitoring station measures the sound every second: LAeq, LCeq and the third-octave bands.
Live status
For each measuring point you see the level now, against the limit that applies there. Green, orange or red.
Screens in the venue
A screen for the DJ, the manager or the guests. On a TV, laptop or tablet, without logging in.
Notifications
A push notification on your phone or an e-mail when the limit is exceeded, or when a monitoring station has lost contact.
Reports
A monthly overview per measuring point per day, and an event report as a PDF.
History
Every night and every day can be reviewed, per quarter of an hour. With a log for complaints and actions.
Share links
A link for the neighbours, the organiser or the municipality. You choose what they see and how long the link works.

How a fixed venue works
Request
You request a quotation. We discuss the rooms, the limit that applies and where the meters go.
Installation and calibration
dB Brothers installs the meters, calibrates them on site and sets the limits.
Account
You get an account as venue manager. You accept the terms digitally and invite colleagues.
Monthly
You pay per month according to the quotation. There is a monthly overview every month. If a meter fails, we see it too.
Who sees what
Venue manager
Sees their venue and the history, creates reports, links and screens. dB Brothers manages the meters.
Administrator and owner
Manages the monitoring stations, the projects, the users and the subscription.
Which limit applies?
That depends on your situation. Two commonly used limits for the audience:
| Limit | Source |
|---|---|
| 103 dB(A), LAeq per 15 minutes | Convenant Preventie Gehoorschade Muziekbranche |
| 100 dB(A), LAeq per 15 minutes | WHO, Global Standard for Safe Listening Venues and Events (2022) |
A permit or the municipality can set a different limit, for example at the facade of the neighbours. You set that limit per measuring point.