How to use the platform, per role. Choose your role and follow the steps. In the admin, the ? button takes you to the part that belongs to your screen.
Venue manager (fixed venue)
For the owner or manager of a bar, club or music venue where dB Brothers has installed the meters.
What you see
After logging in you see your venue: per room the level now, the limit and how often it went over the limit tonight.
The menu contains Overview, History, Log, Screens and Settings.
A night runs from 06:00 to 06:00. An exceedance at 01:30 therefore belongs to the night before.
What you can do
View levels and the history, create reports.
Create share links and screens in the venue.
Keep the log and invite colleagues.
Set up notifications on your phone or by e-mail.
What you do not do
The meters themselves, the installation and the calibration: dB Brothers does that.
The limits: only if dB Brothers has enabled this for your venue.
Reviewing the night
Open your venue and choose History in the menu.
Each bar is a night. Red means that at least one quarter of an hour was over the limit.
Click a bar or a row under Per night. You then see the chart of that night.
With CSV you download the table, for example when someone files a complaint.
View opens the overview on screen. PDF creates a file to keep or send.
The monthly overview shows, per room per day, the highest level, the exceedances and how long measurements were taken. A changed limit is also included.
The overview then shows not measuring, with the time of the last contact.
Check that the monitoring station has power and that the network works. The monitoring station stores its measurements and sends them as soon as it is connected again.
At a fixed venue: report it to dB Brothers. If you want to be notified of this yourself, turn on Meter without contact under My account › Notifications.
Why is the screen red?
Red means that the assessment level is over the limit, for example the LAeq over the last 15 minutes. Orange means that the level is below the limit but within the warning margin.
A short peak does not turn the screen red straight away. A loud period counts until the window has passed. So turn the volume down in time.
What is LAeq per 15 minutes?
The average sound level over a quarter of an hour, energy-averaged. A loud period therefore counts more heavily than a quiet one.
The A (dB(A)) weights the sound the way the ear hears it. LCeq (dB(C)) gives more weight to low tones, such as the bass.
The Convenant Preventie Gehoorschade names 103 dB(A) per 15 minutes. The WHO recommends 100 dB(A) per 15 minutes. Your own limit may differ, for example because of a permit.
Who changes the limits?
At a fixed venue dB Brothers does this, unless dB Brothers has enabled it for your venue. Then the venue manager can change the limits.
With your own subscription, the owner, the administrator and the organiser do this.
Each change is listed in the monthly overview with name, date, and the old and new value.